A stainless steel spout pouring a stream of water into a backyard pool

What Size Pool Pump Do I Need? A Simple Sizing Guide

Gallons, turnover time and GPM in three steps, with a worked example.

Quick answer

Work out your pool's gallons, then divide by 8 hours to get gallons per hour, and divide by 60 to get gallons per minute (GPM). PoolSpaNews says "eight hours can be considered an adequate turnover time" (PoolSpaNews). The pump's flow must not exceed what your plumbing, filter and heater are rated for.

Jump to section
  1. Step 1: work out gallons (3 formulas)
  2. Step 2: pick a turnover time
  3. Step 3: convert to GPM
  4. Match the pump to filter and plumbing
  5. Single vs variable speed: the energy maths
  6. How long to run it
  7. Worked example
  8. Gear that helps
  9. FAQ
  10. Sources

Step 1: work out gallons (3 formulas)

Pump size starts with how much water you have. PoolSpaNews gives three formulas for volume in cubic feet, depending on the pool's shape. Use the average depth in each (PoolSpaNews).

Pool shapeCubic feet
Rectanglelength × width × average depth
Roundradius × radius × 3.14 × average depth
Oval0.785 × length × width × average depth

If the floor slopes, average depth is the shallow end plus the deep end, divided by 2. Then convert to gallons: cubic feet × 7.48 = gallons (PoolSpaNews).

Measure in feet, and use the depth of the water, not the height of the wall.

Use the formula that matches your pool's outline. A round above-ground pool is the easiest, because you only need its radius, which is half the diameter, and its average water depth. An oval pool needs both length and width. If you are not sure which shape you have, measure the longest and shortest distance across the water and compare them.

Step 2: pick a turnover time

Turnover time is how long the pump takes to move the pool's whole volume of water through the filter once. PoolSpaNews says that eight hours can be considered an adequate turnover time (PoolSpaNews). That is the figure we use in this guide.

Divide your gallons by 8 to get the flow you need per hour. If you want a different turnover time, check the maker's manual and the sizing advice for your equipment before you change the number.

Step 3: convert to GPM

Pump labels are often in gallons per minute (GPM), and some are in gallons per hour (GPH). To convert, divide the hourly figure by 60. PoolSpaNews puts it this way: flow rate per hour divided by 60 equals flow rate per minute (PoolSpaNews).

Some pump listings show GPH and others show GPM, so convert before you compare.

That GPM is the flow you need. When you shop, compare it with the flow rate and pool size range in the spec table on our above-ground pool pump page.

That means three numbers matter, not one: the flow your pool needs, the flow your pump delivers and the maximum flow your filter and plumbing allow. The pump's delivered flow should land between the first and the last.

Match the pump to filter and plumbing

A bigger pump is not always better. The pump's flow must not exceed the maximum flow recommended for the plumbing, filter and heater (PoolSpaNews). Too much flow can damage equipment and cause cavitation. Replacing an old pump with a new one of the same horsepower can also push water too fast through the pipes.

PoolSpaNews gives PVC velocity limits: no more than 8 feet per second on the discharge side and no more than 6 feet per second on the suction side (PoolSpaNews). That source is a trade magazine and gives no date, so treat these as guidance and check your manuals.

If you use a sand filter, check its maximum flow in the spec table of our sand filter guide and keep your pump under it.

Before you buy, compare these points in the listing and the manuals:

  • The flow the pump delivers, in GPH or GPM, against the GPM you worked out.
  • The maximum flow of your filter, plumbing and heater.
  • The pump's fitting size against your hoses or pipes.
  • Whether the pump is ENERGY STAR certified, and whether it is single or variable speed.
  • The warranty and what it covers.

Single vs variable speed: the energy maths

ENERGY STAR says that halving a pump's speed means the pump uses one-eighth as much energy, and that variable-speed pumps are quieter (ENERGY STAR). That is why a pump you can slow down saves more than one that only runs at full speed.

For certified models, ENERGY STAR states that certified in-ground pumps use 20% less energy, and certified above-ground pumps use 11% less. A pool pump can be a home's second-largest energy user (ENERGY STAR).

Those percentages are relative to standard pumps, not to your own bill. Your savings depend on your electricity rates and how long you run the pump.

How long to run it

ENERGY STAR says that running the filter 6 hours a day instead of 24 cuts energy use by 75% (ENERGY STAR). The practical rule is to run it long enough to turn the water over, and no longer.

Use the turnover time you chose in step 2 as your starting point, and check your pump's manual for its recommended settings.

Keep testing the water either way. A pump that circulates well still needs a test kit and the right chlorine level.

The numbers worth remembering, all from PoolSpaNews (PoolSpaNews):

ItemFigure
Adequate turnover time8 hours
Gallons per hour to gallons per minuteDivide by 60
Cubic feet to gallonsMultiply by 7.48
PVC discharge velocityNo more than 8 feet per second
PVC suction velocityNo more than 6 feet per second

Keep this table next to the spec table on the pump page when you compare models.

Worked example

Take a pool with a volume of 15,000 gallons. This is our own arithmetic, built from the two rules above.

  1. Turnover time of 8 hours: 15,000 gallons ÷ 8 hours = 1,875 gallons per hour.
  2. Convert to minutes: 1,875 ÷ 60 = 31.25 GPM.

To check the arithmetic, work backwards: 31.25 GPM × 60 = 1,875 gallons per hour, and 1,875 × 8 hours = 15,000 gallons. The numbers close the loop.

So you would look for a pump that delivers about 31.25 GPM at your pool's real operating conditions, and that stays within the maximum flow of your filter and plumbing. Then check its listed pool size range and flow in the spec table before you buy.

If a pump is rated well above your result, make sure the filter can take it. If a pump is rated below it, the water will turn over more slowly than you planned.

Gear that helps

FAQ

How do I turn gallons per hour into gallons per minute?

Divide by 60. Flow rate per hour divided by 60 gives flow rate per minute, or GPM (PoolSpaNews).

Does running the pump less save energy?

Yes. Running the filter 6 hours a day instead of 24 cuts energy use by 75% (ENERGY STAR).

Can I replace my pump with one of the same horsepower?

Take care. A new pump of the same horsepower as an old one can push water too fast through the pipes (PoolSpaNews).